Vous êtes dans notre catalogue de produits
English | Italiano | Deutsch

C058067A - Rev. 0

Pt1000 RTD SENSOR FOR CRYOGENIC APPLICATIONS, -100...200°C, IP68
RTD sensor with Ø4.0X40mm s.s. tube and direct cable
- Single element RTD Pt1000 CL.B ; - Working temperature range : -100...200°C ; - Ø4.0mm stainless steel tube ; - 2-wire cable, double insulation PFA/PFA .
Need Help?
Sales Team
We will get back to you within 2 business days
Spécifications techniques
Sensing element
Pt1000 Ω @ 0°C
Sensing Element configuration
single 2-wire
Output signal type
thermoresistance
Accuracy class in accordance to IEC751 (*)
(*) The accuracy class is valid only in the temperature range indicated by the norm
cl. B
Working temperature
-100 ÷200°C
Insulation resistance
100 M Ω@ 100 Vdc.
Sheath outside diameter d
Ø 4 mm
Sheath length L
40 mm
Sheet material
INOX
Cable extension E
1500 mm
International protection marking (*)
(*) According to IEC 60529
IP68
EXTENSION CABLE
Cable conductors
copper tinned
Number of cable conductors
2
Conductor dimension
AWG 24
Conductor feature
strand (7 wire)
Primary insulation
PFA
Outside diameter of single conductor (*)
(*) primary insulation
about Ø 1 mm
Primary insulation colour
2 white
Secondary insulation
PFA
Secondary insulation colour
black
Cable size or external shape
about Ø 2,5 mm
twistato
RTD
Sensing element
Pt1000 Ω @ 0°C
Accuracy class in accordance to IEC751 (*)
(*) The accuracy class is valid only in the temperature range indicated by the norm
cl. A
Sheath diameter d
Not indicated
Downloads
Media