9 ÷32 Vdc (polarity protected)
for digital sensors with I2CBus interface
Power supplied to sensor 3.3Vdc max 5mA
refer to the specific graphs
Temp: ± 0.3°C @ -40÷ 90°C
refer to the technical data of the sensor installed
<4mA with RS485 (<10mA at power on for approx. 8mS)
Modbus RTU (max. baud rate 38.400)
Maximum connection distance
1000 meters, this distance depends on the power supply voltage and the type of cable used to connect the various devices
Maximum devices on network
Maximum 256 nodes (it is recommended to use isolators / repeaters along the serial line)
Blue LED, power supply and device operations indicator
Red LED (ERR), sensor error indicator
White LEDs (TX and RX), serial transmission and reception indicators
In accordance to BS EN 61326-1 (UKCA)
In accordance to EN 61326-1 (CE)
By using the EVOPLATFORMSET configuration kit (a PC with Windows OS is required).