BackBack

TCEJHT - Rev. 1

THERMOCOUPLE TYPE J Ø 3 - 4,5 mm WITH INTEGRATED CABLE

Compact mineral insulated thermocouple type J (M.I.C.) with metallic transition H.T. and compensated cable

-wide range of diameters and lengths achievable -Transition T° MAX 260°C -Various types of extension cable insulation -sensitive part for T° over 600°C

  • Product Datasheet
  • Download
  • Videos

Technical Specifications

Thermocouple calibration
type J (iron-constantan)
Sheet material
AISI 304
Number of sensing elements (T/C)
single
double
Hot measuring joint
insulated
grounded
Output signal type
thermocouple
Accuracy class in accordance with IEC 584
special
standard
Sheath diameter d
Ø 3 mm
Sensing part maximum working temperature 520°C
Ø 4.5 mm
Sensing part maximum working temperature 620°C
M.I.C. min. bending radius
3 times the outer diameter
Insulation resistance
100 M Ω@ 100 Vdc.
Realizable sheat lenghts L= (subject to feasibility check)
50 mm ÷50 m
Transition sleeve type
METALLIC Ø 6 mm H.T.
Transition sleeve diameter
Ø 6 mm
Transition sleeve length
30 mm
Transition sleeve material
STAINLESS
Maximum transition temperature
260°C
Compensated cable
reinforced fibreglass; type J DIN
Maximum working temperature 350°C (200°C structural limit of sheath)
FEP; type J ANSI
Working temperature -65 ÷ 200°C
reinforced fibreglass; type J IEC
Maximum working temperature 350°C
rigid kapton; type J IEC
Working temperature -55 ÷ 200°C
PTFE + Kapton + Kapton; type J IEC
Working temperature -200 ÷ 200°C
Cable lenghts E= (subject to feasibility check)
500 mm ÷50 m