Technical Specifications
Thermocouple calibration
type T (copper-constantan)
Sheet material
AISI 316L
Sensing element operating temperature range
-200 ÷260°C
Number of sensing elements (T/C)
single
Hot measuring joint
grounded
insulated
Output signal type
thermocouple
Accuracy class in accordance with IEC 584
special
standard
Sheath diameter d
Ø 0.5 mm
M.I.C. min. bending radius
3 times the outer diameter
Insulation resistance
100 M Ω@ 50 Vdc.
Realizable sheat lenghts L= (subject to feasibility check)
20 mm ÷1000 mm
Transition sleeve type
METALLIC Ø 6 mm L.T.
Transition sleeve diameter
Ø 6 mm
Transition sleeve length
30 mm
Transition sleeve material
STAINLESS
Maximum transition temperature
120°C
Compensated cable
silicone; type T ANSI
Cable lenghts E= (subject to feasibility check)
300 mm ÷4 m