Technical Specifications
Thermocouple calibration
type J (iron-constantan)
Sheet material AISI 304
Sensing part maximum working temperature 260°C
type K (cromel-alumel)
Sheet material INCONEL 600
Sensing part maximum working temperature 700°C
Number of sensing elements (T/C)
single
Hot measuring joint
insulated
Norm of reference
ANSI MC96.1
IEC 584
Accuracy class in accordance with IEC 584
special
standard
Sheath diameter d
Ø 0.5 mm
M.I.C. min. bending radius
3 times the outer diameter
Insulation resistance
100 M Ω@ 50 Vdc.
Realizable sheat lenghts L= (subject to feasibility check)
50 mm ÷5000 mm
Type of connector
normalised MALE MINIATURE SIZE OVERMOULDED compensated connector (in accordance with ASTM E 1684-96)
Connector remarks at our discretion (depending on the quantity to be produced) the connector could be assembled by hand instead of being OVERMOULDED
Connection body material
POLYAMYDE (MOULDED)
Maximum connector temperature
120°C (200°C for 1 hour)