Technical Specifications
Thermocouple calibration
type J (iron-constantan)
Sheet material AISI 304
Sensing part maximum working temperature 600°C
type K (cromel-alumel)
Sheet material INCONEL 600
Sensing part maximum working temperature 1150°C
Number of sensing elements (T/C)
double
single
Norm of reference
IEC 584
Hot measuring joint
insulated
Output signal type
thermocouple
Accuracy class in accordance with IEC 584
special
standard
M.I.C. min. bending radius
3 times the outer diameter
Insulation resistance
100 M Ω@ 100 Vdc.
Sheath diameter d
Ø 3 mm
Ø 4.5 mm
Ø 6 mm
Stem length L
250 mm
500 mm
1000 mm
1500 mm
Dimensional notes
Lengths other than those listed can be produced for minimum quantities to be agreed (after our feasibility study)
Type of connector
male connector having contacts with M12x1 metal screw lock (in accordance with IEC 61076-2-101 STANDARDS)
Connection body material
POLYAMYDE (MOULDED)
Maximum connector temperature
120°C
International protection marking (*)
(*) According to IEC 60529
IP67