Sie befinden sich jetzt in unserem Produktkatalog
Italiano | English | Français

IOD- - Rev. 2

EVOMINI IOD-
Temperature transmitter with IO-Link interface, stainless steel construction with connection for food thermowells
Can be configured in three operating modes: IO-Link, 4-20mA loop powered and switching output with alarm thresholds (SIO). Full stainless steel construction with M12 output connector and IP67 protection degree. Process connection by Italcoppie Sensori TWF (DIN 11851/Tri-clamp) thermowells. Particularly suitable for food, chemical and pharmaceutical industry applications.
SIE BRAUCHEN UNTERSTÜTZUNG?
Technische Beratung
Wir melden uns innerhalb eines Arbeitstags bei Ihnen
Technische Daten
Electrical technical data for Evomini IO-Link (only models with integrated probe)
Betriebstemperatur Leiterplatte
-40 ÷80°C
Storage temperature
-40 ÷80°C
Betriebsfeuchtigkeit
0 ÷100%
Operating Voltage
18÷32 Vdc reverse polarity protection (IO-Link operating mode)
8÷32 Vdc reverse polarity protection (Loop Powered operating mode)
Stromverbrauch
0.65 W (IO-Link operating mode) 0.8 W (SIO operating mode)
Ein-/Ausgänge isoliert
Keine
Sensoreingang Signalfilter (*)
(*) Zeit bis zum Erreichen von 90 % des Signals
Configurable from 0.1s to 3.7s
Ausgangssignal
Configurable between: 4÷20mA analogue signal; IO-Link; switching PNP or NPN output (SIO);
zulässige Last
727Ω @ 24 Vdc [Rload= (Vpw. - 8) / 0,022] (Loop Powered operating mode)
Sensorbruch- oder Kurzschluss-Überwachung
Nach NAMUR NE43 wählbar zwischen:
Upper scale (> 21.0 mA)
Lower scale (< 3,6 mA)
(Loop Powered operating mode )
Communication interface
IO-Link Vers. 1.1 (COM2 - 38,4Kbaud)
Class A port
M12x1 - 4 pos. A-coded
IO-Link Smart Sensor Profile (2nd ed.)
According to SSP type 3.1
Switching output (*)
(*) SIO operating mode
NO/NC programmable, PNP/NPN
Overload and short circuit protection
Hysteresis or window function
Maximum current: 150mA
Programmable output activation/deactivation delay
RGB LED for output status signaling (configurable color for OFF state and ON state)
Display elements (*)
(*) IO-Link operating mode
Green color LED (IO-Link), RGB LED with configurable color (Locator), RGB LED with configurable color (SIO)
Temperatureinfluss (*)
(*) Abweichung von 20 °C
Maximum value between ±0,3°C/25°C and ±0,3% of span/25°C (Loop powered operating mode)
±0,3°C/25°C (IO-Link and SIO operating mode)
Langzeitstabilität
maximal 0,1 % des Messbereichs pro Jahr
Linearer Fehler
vernachlässigbar
Sensor Fehlerkompensation
Offset or over two points
EMV
In accordance to EN 61326-1:2013 (CE)
In accordance to BS EN 61326-1:2013 (UKCA)
Messbereich
-50 ÷350°C
Genauigkeit
Maximum value between ±0.15K and ±0.15% of span (Loop Powered operating mode)
±0.1K (IO-Link operating mode)
Anschluss Material
Edelstahl AISI 316L
Steckverbinder-Typ
Steckverbinder M12x1 male, 4 Pins, nach DIN EN IEC 61076-2-101
Fühlerkonstruktion
mineralisoliert
Insulation resistance
100 M Ω
Mantelmaterial
AISI 316L
Manteldurchmesser
Ø 3 mm
Prozessanschluss (*)
(*) Gewindenormen (ZYL. GAS gemäß UNI-ISO 228) (KON. GAS gemäß UNI-ISO 7-1) (NPT gemäß ANSI B 1.20.1)
Tauchhülsen der TWF-Serie (ohne TWF2)
Pt100 Sensor Genauigkeit
Klasse A bis zu 300 °C nach IEC 751
IP-Schutzart (*)
(*) Gemäß IEC 60529
IP67
Programming
With any IO-Link programmation platform and the relative master.
Option
Auf Wunsch Justierung an 1 oder 2 Temperaturpunkten
Werkskonfiguration
Loop powered operating mode: (4÷20)mA output / Range 0÷150°C / Sensor break ≥21mA / Sensor short-circuit ≤3.6mA
Switching output operating mode (SIO): PNP type output with hysteresis function NO, SP=80°C, RSP=70°C, no delay, output status signaling: LED color red
Downloads
Datenblatt
ic_datasheet_iod-_de.pdf[4,99 MB]
Zertifizierungen
DC_0025462.pdf[89,65 KB]
Media