You are now in our product catalog
Italiano | Deutsch | Français

A076005A - Rev. 0

FLAT RTD FOR ELECTRICAL MACHINES
Suitable for stator winding
Thermoresistance Pt100 ohm Class B Double element 3+3 wires Flat fiberglass case, 12x2,5x340mm Sensing part R=160mm Cable 6x24AWG fluorine polymer insulated L= 15000mm
Need Help?
Sales Team
We will get back to you within 2 business days
Technical specifications
Output signal type
thermoresistance
Sensing element
Pt100 Ω @ 0°C
Sensing Element configuration
single 3-wire
double 6-wire
multiple points cartridge RTD
Accuracy class in accordance to IEC751 (*)
(*) The accuracy class is valid only in the temperature range indicated by the norm
cl. B
Sensing element operating temperature range
-10 ÷150°C (180°C per brevi periodi)
Insulation resistance
10 G Ω@ 2500 Vdc.
Dielectric strength
5000 Vac
Maximum working humidity
95%
Vibration resistance (secondo IEC 68-2-6, test Fc)
4g (peak) ;15-250 Hz
Sheet material
High temperature FIBREGLASS, type FR5
Stem length L
180 mm
1000 mm
Length of sensing part
50 mm
160 mm
stem width
10 mm
40 mm
Distance of sensing element from probe tip Z
Customer's specifications
Stem thickness
2.5 mm
5 mm
Extension cable
ETFE rame stagnato a 3 conduttori trefolo 24 AWG
ETFE rame stagnato a 6 conduttori trefolo 24 AWG
Cable extension E
100 mm
30 m
Downloads
Data sheet
ic_datasheet_a076005a_en.pdf[0,83 MB]
Media